LINE-FLUID ACTUATED VALVE
The Hydrocore Line-Fluid Actuated valve is used for remote isolating of pipeline applications by using the line-fluid pressure. Is mainly used in: Industrial Water Systems, Municipal Water Supply Systems, Pump Stations, Mine Water Reticulation and Petrochemical Plants.
​
Benefits of the Hydrocore Line-Fluid Actuated Valve
-
No electric actuators that are expensive and that have limit switches that are seldom set correctly causing the valve to fail.
-
No gears, spindle, bushes, shafts, keys and keyways that can wear out and cause the limit switch to go out or cause the actuator to fail.
-
The valve has a superior Cv compared to other globe valves.
-
No pneumatic systems.
-
The needle valve can be set very accurately so that the valve closes at an appropriate speed so as to prevent the occurrence of water hammer.
-
The valve always has positive pressure (full column pressure) on top of the shuttle when the valve is in a closed position. This prevents valve seat leakage and seat damage. When the valve is in an open position, it prevents the valve from being in a partly open position. This ensures that there is no reduced pressure drop over the valve causing undesired energy and financial losses.
FEATURES
-
Does not need an expensive actuator to operate
-
Does not need a gears, spindle, bushes, shafts, keys and keyways that can wear out and cause the limit switch to go out or cause the actuator to fail.
-
​No pneumatic systems.
-
Superior flow coefficient (Cv/Kv)
-
Can be maintained in line
-
High cavitation resistance due to design
-
Stainless steel moving internals parts
-
Cast steel body
-
Low pressure drop across valve
-
Flanges and face-to-face dimensions to customer specification
SPECIFICATIONS
FLOW COEFFICIENTS & FLOW RATES
Pressure rating
160 bar (max) working pressure
​
Temperature rating
Up to 85ºC with standard seals.
​
Media
Liquid and gas with low content of suspended solids.
​
Pipe sizes
2” (50 NB) to 16” (400 NB)
​
Flanges
SABS 1123, BS4504, BS10, ASME B16.34, ANSI B16.5
​
pH levels & chlorides
Parts of the valve are made from stainless steel and can withstand a low level of chlorides.
​
Installation position
The valve can be installed in any position
Seating
Seat Leakage - B16.104 class III, IV, V or VI, depends on valve type and application.
150 NB
Cv/Kv: 525 | Flow (max): 117 â„“/sec | ΔP: 12.5 psi
​
200 NB
Cv/Kv: 1086 | Flow (max): 152 â„“/sec | ΔP: 1.4 psi
​
250 NB
Cv/Kv: 1433 | Flow (max): 233 â„“/sec | ΔP: 6.7 psi
​
300 NB
Cv/Kv: 1936 | Flow (max): 337 â„“/sec | ΔP: 7.9 psi
DIMENSIONS AND WEIGHTS
SIZE
150 NB
​
200 NB
​
250 NB
​
300 NB
A (mm)
​
381
​
494
​
573
​
652
B (mm)
​
381
​
480
​
573
​
645
C (mm)
​
711
​
913
​
1059
​
1198
#150 F-T-F
559mm / 229kg
​
660mm / 405kg
​
787mm / 744kg
​
838mm / 1052kg
#300 F-T-F
59mm / 245kg
​
660mm / 429kg
​
787mm / 778kg
​
838mm / 1098kg
#600 F-T-F
559mm / 270kg
​
660mm / 460kg
​
787mm / 840kg
​
838mm / 1164kg
#900 F-T-F
​
610mm / 297kg
​
737mm / 509kg
​
838mm / 891kg
​
965mm / 1277kg
#1500 F-T-F
​
705mm / TBD
​
832mm / TBD
​
991mm / TBD
​
1130mm / TBD